This is the latest recevied telemetry packets stored in our database for station/object OK1FWG-6. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
---|---|---|---|---|---|
1753543373 | 617 Count | 600 Count | 407 Count | 3.83 VDC | 0 VDC |
1753541570 | 611 Count | 584 Count | 402 Count | 3.85 VDC | 0 VDC |
1753539767 | 605 Count | 567 Count | 397 Count | 3.87 VDC | 0 VDC |
1753537963 | 590 Count | 541 Count | 383 Count | 3.87 VDC | 0 VDC |
1753536161 | 562 Count | 503 Count | 356 Count | 3.89 VDC | 0 VDC |
1753534357 | 545 Count | 484 Count | 340 Count | 3.84 VDC | 0 VDC |
1753532554 | 528 Count | 461 Count | 324 Count | 3.89 VDC | 0 VDC |
1753530746 | 523 Count | 444 Count | 321 Count | 3.91 VDC | 0 VDC |
1753528943 | 517 Count | 425 Count | 316 Count | 3.88 VDC | 0 VDC |
1753527140 | 510 Count | 410 Count | 310 Count | 3.9 VDC | 0 VDC |
1753525337 | 507 Count | 396 Count | 308 Count | 3.9 VDC | 0 VDC |
1753523533 | 501 Count | 391 Count | 306 Count | 3.92 VDC | 0 VDC |
1753521730 | 494 Count | 384 Count | 300 Count | 3.84 VDC | 0 VDC |
1753519926 | 491 Count | 382 Count | 298 Count | 3.87 VDC | 0 VDC |
1753518123 | 488 Count | 379 Count | 296 Count | 3.92 VDC | 0 VDC |
1753516320 | 482 Count | 376 Count | 293 Count | 3.86 VDC | 0 VDC |
1753514517 | 465 Count | 361 Count | 278 Count | 3.85 VDC | 0 VDC |
1753512714 | 455 Count | 352 Count | 269 Count | 3.87 VDC | 0 VDC |
1753510911 | 452 Count | 350 Count | 267 Count | 3.88 VDC | 0 VDC |
1753509108 | 447 Count | 348 Count | 265 Count | 3.92 VDC | 0 VDC |
1753507305 | 444 Count | 345 Count | 263 Count | 3.87 VDC | 0 VDC |
1753505502 | 441 Count | 343 Count | 261 Count | 3.93 VDC | 0 VDC |
1753503699 | 438 Count | 340 Count | 259 Count | 3.89 VDC | 0 VDC |
1753502047 | 435 Count | 338 Count | 257 Count | 3.85 VDC | 0 VDC |
1753500244 | 432 Count | 335 Count | 255 Count | 3.88 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)