This is the latest recevied telemetry packets stored in our database for station/object GW3ATZ-10. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1781928812 | 512 Count | 612 Count | 390 Count | 4.25 VDC | 0.14 VDC |
| 1781927004 | 504 Count | 600 Count | 384 Count | 4.23 VDC | 0.14 VDC |
| 1781925195 | 496 Count | 587 Count | 378 Count | 4.21 VDC | 0.14 VDC |
| 1781923387 | 488 Count | 575 Count | 372 Count | 4.19 VDC | 0.14 VDC |
| 1781921579 | 480 Count | 562 Count | 366 Count | 4.24 VDC | 0.14 VDC |
| 1781919771 | 472 Count | 549 Count | 360 Count | 4.25 VDC | 0.14 VDC |
| 1781917963 | 464 Count | 536 Count | 354 Count | 4.26 VDC | 0.14 VDC |
| 1781916252 | 456 Count | 524 Count | 348 Count | 4.23 VDC | 0.14 VDC |
| 1781914443 | 448 Count | 511 Count | 342 Count | 4.19 VDC | 0.14 VDC |
| 1781912635 | 440 Count | 503 Count | 336 Count | 4.22 VDC | 0.14 VDC |
| 1781910827 | 432 Count | 495 Count | 330 Count | 4.26 VDC | 0.14 VDC |
| 1781909019 | 424 Count | 487 Count | 324 Count | 4.21 VDC | 0.14 VDC |
| 1781907210 | 416 Count | 479 Count | 318 Count | 4.25 VDC | 0.14 VDC |
| 1781905402 | 408 Count | 471 Count | 312 Count | 4.23 VDC | 0.14 VDC |
| 1781903594 | 400 Count | 463 Count | 306 Count | 4.23 VDC | 0.14 VDC |
| 1781901786 | 392 Count | 455 Count | 300 Count | 4.24 VDC | 0.14 VDC |
| 1781899978 | 384 Count | 447 Count | 294 Count | 4.25 VDC | 0.14 VDC |
| 1781898169 | 376 Count | 439 Count | 288 Count | 4.19 VDC | 0.14 VDC |
| 1781896361 | 368 Count | 429 Count | 282 Count | 4.24 VDC | 0.14 VDC |
| 1781894652 | 360 Count | 421 Count | 276 Count | 4.22 VDC | 0.14 VDC |
| 1781892844 | 352 Count | 412 Count | 270 Count | 4.22 VDC | 0.14 VDC |
| 1781891035 | 344 Count | 403 Count | 264 Count | 4.23 VDC | 0.14 VDC |
| 1781889227 | 336 Count | 394 Count | 258 Count | 4.23 VDC | 0.14 VDC |
| 1781887419 | 328 Count | 385 Count | 252 Count | 4.23 VDC | 0.14 VDC |
| 1781885610 | 320 Count | 376 Count | 246 Count | 4.25 VDC | 0.14 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)